Sun Fire X4100 - Remote Control via ilom not working

Dear all

I am having troubles with the Remote Control feature integrated in the Sun Fire X4100 ilom.

When I click on the "Launch Redirection" button nothing happens. I just have the "Analyzing configuration" text but nothing more.

I have tried in both 8bit and 16bit modes with same result. I also tried using IE and Firebird with no more luck.

More over, the only way to get control back on the web interface is to reset the SP via ssh.

I am using firmware 1.1.1.

I have done some network sniffing and the last two things done are this GET request :

GET /RPC/getka.asp?quid=<somethinglong>& HTTP/1.1

The two quid are different in the two requests.

Does any have an idea to help me ?

Many thanks

--

Eric

[792 byte] By [edechauxa] at [2007-11-27 8:58:18]
# 1
Well, yet another untested feature before release... It's a known bug that has been fixed in firmware 1.1.8.After update it now works. 19 firmware updates to go...
edechauxa at 2007-7-12 21:24:08 > top of Java-index,Sun Hardware,Servers - General Discussion...