Fiber Channel configuration
Hi,
i kind of new with the SUN environment, but still this past few weeks i got my all over my hands with problems that i could find the solution over some forums or other sources.
But here is one that i can't find any solution, so if anybody could give me a hint on this, that would be great.
I have one StorEdge A5000 14 slot connected with a Enterprise 4500 server. Solaris 5.10 installed.
The problem is the HBA connectivity.
I explain:
StroEdge configuration, is single loop, i'm using the two server fiber adapters to provide dual path to the disks using the A1 and B0 GBIC.
On PROM, a probe-fcal-all command will display me all drivers on two different path, first and second adapter.
While i'm on solaris[code]luxadm display SUN01A
SENA
DISK STATUS
SLOTFRONT DISKS(Node WWN) REAR DISKS(Node WWN)
0On (O.K.) 20000020372015a3On (O.K.) 2000002037200353
1On (O.K.) 20000020372002c3On (O.K.) 2000002037201aa6
2On (O.K.) 2000002037200e1aOn (O.K.) 20000020372012e1
3On (O.K.) 200000203720032eOn (O.K.) 2000002037175c88
4On (O.K.) 2000002037511147On (O.K.) 200000203717f4c9
5On (O.K.) 20000020372014dbOn (O.K.) 2000002037200d73
6On (O.K.) 2000002037201783On (O.K.) 200000203717fec5
SUBSYSTEM STATUS
FW Revision:1.09Box ID:1Node WWN:508002000006ad50Enclosure Name:SUN01A
Power Supplies (0,2 in front, 1 in rear)
0 O.K.(rev.-02) 1 O.K.(rev.-02) 2 O.K.(rev.-02)
Fans (0 in front, 1 in rear)
0 O.K.(rev.-04) 1 O.K.(rev.-00)
ESI Interface board(IB) (A top, B bottom)
A: O.K.(rev.-04)
GBIC module (1 on left, 0 on right in IB)
0 Failed(mod.-05): Not receiving a signal
1 O.K.(mod.-05)
B: O.K.(rev.-04)
GBIC module (1 on left, 0 on right in IB)
0 O.K.(mod.-05)
1 Failed(mod.-05): Not receiving a signal
Disk backplane (0 in front, 1 in rear)
Front Backplane: O.K.(rev.-04)
Temperature sensors (on front backplane)
0:40篊 1:42篊 2:40篊 3:37篊 4:40篊 5:42篊
6:42篊 (All temperatures are NORMAL.)
Rear Backplane: O.K.(rev.-04)
Temperature sensors (on rear backplane)
0:39篊 1:37篊 2:39篊 3:37篊 4:39篊 5:40篊
6:42篊 (All temperatures are NORMAL.)
Interconnect assembly
O.K.(rev.-02)
Loop configuration
Loop A is configured as a single loop.
Loop B is configured as a single loop.
LanguageUSA English
[/code]
[code]
# format
Searching for disks...done
AVAILABLE DISK SELECTIONS:
0. c0t2d0
/sbus@3,0/SUNW,fas@3,8800000/sd@2,0
1. c0t3d0
/sbus@3,0/SUNW,fas@3,8800000/sd@3,0
2. c1t32d0
/sbus@3,0/SUNW,socal@0,0/sf@0,0/ssd@w22000020372015a3,0
3. c1t33d0
/sbus@3,0/SUNW,socal@0,0/sf@0,0/ssd@w22000020372002c3,0
4. c1t34d0
/sbus@3,0/SUNW,socal@0,0/sf@0,0/ssd@w2200002037200e1a,0
5. c1t35d0
/sbus@3,0/SUNW,socal@0,0/sf@0,0/ssd@w220000203720032e,0
6. c1t36d0
/sbus@3,0/SUNW,socal@0,0/sf@0,0/ssd@w2200002037511147,0
7. c1t37d0
/sbus@3,0/SUNW,socal@0,0/sf@0,0/ssd@w22000020372014db,0
8. c1t38d0
/sbus@3,0/SUNW,socal@0,0/sf@0,0/ssd@w2200002037201783,0
9. c1t48d0
/sbus@3,0/SUNW,socal@0,0/sf@0,0/ssd@w2200002037200353,0
10. c1t49d0
/sbus@3,0/SUNW,socal@0,0/sf@0,0/ssd@w2200002037201aa6,0
11. c1t50d0
/sbus@3,0/SUNW,socal@0,0/sf@0,0/ssd@w22000020372012e1,0
12. c1t51d0
/sbus@3,0/SUNW,socal@0,0/sf@0,0/ssd@w2200002037175c88,0
13. c1t52d0
/sbus@3,0/SUNW,socal@0,0/sf@0,0/ssd@w220000203717f4c9,0
14. c1t53d0
/sbus@3,0/SUNW,socal@0,0/sf@0,0/ssd@w2200002037200d73,0
15. c1t54d0
/sbus@3,0/SUNW,socal@0,0/sf@0,0/ssd@w220000203717fec5,0
16. c2t32d0
/sbus@7,0/SUNW,socal@0,0/sf@0,0/ssd@w21000020372015a3,0
17. c2t33d0
/sbus@7,0/SUNW,socal@0,0/sf@0,0/ssd@w21000020372002c3,0
18. c2t34d0
/sbus@7,0/SUNW,socal@0,0/sf@0,0/ssd@w2100002037200e1a,0
19. c2t35d0
/sbus@7,0/SUNW,socal@0,0/sf@0,0/ssd@w210000203720032e,0
20. c2t36d0
/sbus@7,0/SUNW,socal@0,0/sf@0,0/ssd@w2100002037511147,0
21. c2t37d0
/sbus@7,0/SUNW,socal@0,0/sf@0,0/ssd@w21000020372014db,0
22. c2t38d0
/sbus@7,0/SUNW,socal@0,0/sf@0,0/ssd@w2100002037201783,0
23. c2t48d0
/sbus@7,0/SUNW,socal@0,0/sf@0,0/ssd@w2100002037200353,0
24. c2t49d0
/sbus@7,0/SUNW,socal@0,0/sf@0,0/ssd@w2100002037201aa6,0
25. c2t50d0
/sbus@7,0/SUNW,socal@0,0/sf@0,0/ssd@w21000020372012e1,0
26. c2t51d0
/sbus@7,0/SUNW,socal@0,0/sf@0,0/ssd@w2100002037175c88,0
27. c2t52d0
/sbus@7,0/SUNW,socal@0,0/sf@0,0/ssd@w210000203717f4c9,0
28. c2t53d0
/sbus@7,0/SUNW,socal@0,0/sf@0,0/ssd@w2100002037200d73,0
29. c2t54d0
/sbus@7,0/SUNW,socal@0,0/sf@0,0/ssd@w210000203717fec5,0
[/code]
So now i was trying to define the failover path using mpathadm command as documented on the 'Solaris Fiber Channel and Storage Multipathing Administration Guide' but
# mpathlistlu command show no lines
so i looked further to find out what is happening and i found some other documents talking about the Dynamic Configuration and the cfgadm command
so here is the output of cfgadm
[code]
# cfgadm
Ap_Id Type ReceptacleOccupantCondition
ac0:bank0 memoryconnectedconfiguredok
ac0:bank1 memoryemptyunconfigured unknown
ac1:bank0 memoryconnectedconfiguredok
ac1:bank1 memoryemptyunconfigured unknown
c0scsi-busconnectedconfiguredunknown
c8scsi-busconnectedunconfigured unknown
sysctrl0:slot0cpu/memconnectedconfiguredok
sysctrl0:slot1soc+sbusconnectedconfiguredok
sysctrl0:slot2cpu/memconnectedconfiguredok
sysctrl0:slot3soc+sbusconnectedconfiguredok
sysctrl0:slot4unknownemptyunconfigured unknown
sysctrl0:slot5unknownemptyunconfigured unusable
sysctrl0:slot6unknownemptyunconfigured unknown
sysctrl0:slot7unknownemptyunconfigured unusable
[/code]
no what i don't understand, is where are my c1 and c2 fibers ?
i tryed the cfgadm with configure subcommand using the StorEdge WWN but no luck
[code]
# cfgadm configure WWN:508002000006ad50
Ap_Id Type ReceptacleOccupantCondition
configure : No matching library found
WWN:508002000006ad50 : No matching library found
[/code]
i'm taking any suggestions.
Thanks
PS: i tryed everything to format corectly this message, the code tags are no use ... i'm sorry for this inconvenient
Message was edited by:
Adrian.Aldea