T1000 ldmd start issues

Anyone run in to this one?

ldmd fails to start after installation, ldmd svcs log is as follows

bash-3.00# tail /var/svc/log/ldoms-ldmd:default.log

[cut-n-paste out success]

fatal error: Missingmax_mblocks property in firmware node of PRI.

Please check that the LDom Manager version is compatible

with the installed firmware.

Note firmware and patches up to spec on Sol10 11/06

bash-3.00# sc> showhost

Sun-Fire-T1000 System Firmware 6.4.0_build_07 2007/02/14 22:09

Host flash versions:

Hypervisor 1.4.0_build_07 2007/02/14 21:52

OBP 4.26.0.build_07 2007/02/14 19:20

POST 4.26.0.build_07 2007/02/14 19:52

[698 byte] By [nge.confa] at [2007-11-27 3:24:52]
# 1
For those interested here's the solution.Firmware 6.4.0 was the problem - bugs. I downloaded patch 126400-01 and installed Firmware 6.4.4. This fixed my problem.Primary doman running.. fun to start next
nge.confa at 2007-7-12 8:27:39 > top of Java-index,Administration Tools,Logical Domains for CoolThreads Servers...