[ID 107833 kern.warning] ... /scsi_vhci/....

Hi there,

Have noticed these errors in dmesg log and seems like during this period of errors we had our systems have a very low transfer rate.

I have 3 sets of erros to dig into.

[1] I did some search and found a similar error and had a patch for the specific device ...(reference http://sunsolve.sun.com/search/document.do?assetkey=1-26-101771-1). Errors are attached below

[2] SAM-FS critical device error. Not sure on if this is critical, and how to go about finding the source of the problem.

[3] output of iostat -En ....showing 2 hard errors. is this the source of all problems above ?

Thanks for any help you can provide!!!

~a2@sunsolve

[1] =============================================

Nov 23 01:00:13 suseme scsi: [ID 107833 kern.warning] WARNING: /scsi_vhci/ssd@g600a0b80001732a600002f0b4290b53e (ssd21):

Nov 23 01:00:13 suseme Error for Command: write(10)Error Level: Retryable

Nov 23 01:00:13 suseme scsi: [ID 107833 kern.notice]Requested Block: 302073600Error Block: 302073600

Nov 23 01:00:13 suseme scsi: [ID 107833 kern.notice]Vendor: SUNSerial Number:

Nov 23 01:00:13 suseme scsi: [ID 107833 kern.notice]Sense Key: Unit Attention

Nov 23 01:00:13 suseme scsi: [ID 107833 kern.notice]ASC: 0xc (write error), ASCQ: 0x0, FRU: 0x0

Nov 23 01:00:25 suseme scsi: [ID 107833 kern.warning] WARNING: /scsi_vhci/ssd@g600a0b80001732a600002f084290b04e (ssd51):

Nov 23 01:00:25 suseme Error for Command: write(10)Error Level: Retryable

Nov 23 01:00:25 suseme scsi: [ID 107833 kern.notice]Requested Block: 418872392Error Block: 418872392

Nov 23 01:00:25 suseme scsi: [ID 107833 kern.notice]Vendor: SUNSerial Number:

Nov 23 01:00:25 suseme scsi: [ID 107833 kern.notice]Sense Key: Unit Attention

Nov 23 01:00:25 suseme scsi: [ID 107833 kern.notice]ASC: 0xc (write error), ASCQ: 0x0, FRU: 0x0

Nov 23 01:00:25 suseme scsi: [ID 107833 kern.warning] WARNING: /scsi_vhci/ssd@g600a0b8000178ac0000026714290b04b (ssd50):

Nov 23 01:00:25 suseme Error for Command: write(10)Error Level: Retryable

Nov 23 01:00:25 suseme scsi: [ID 107833 kern.notice]Requested Block: 304059616Error Block: 304059616

Nov 23 01:00:25 suseme scsi: [ID 107833 kern.notice]Vendor: SUNSerial Number:

Nov 23 01:00:25 suseme scsi: [ID 107833 kern.notice]Sense Key: Unit Attention

Nov 23 01:00:25 suseme scsi: [ID 107833 kern.notice]ASC: 0xc (write error), ASCQ: 0x0, FRU: 0x0

Nov 23 01:00:33 suseme scsi: [ID 107833 kern.warning] WARNING: /scsi_vhci/ssd@g600a0b8000178ac00000267442913027 (ssd20):

Nov 23 01:00:33 suseme Error for Command: write(10)Error Level: Retryable

Nov 23 01:00:33 suseme scsi: [ID 107833 kern.notice]Requested Block: 4 Error Block: 4

Nov 23 01:00:33 suseme scsi: [ID 107833 kern.notice]Vendor: SUNSerial Number:

Nov 23 01:00:33 suseme scsi: [ID 107833 kern.notice]Sense Key: Unit Attention

Nov 23 01:00:33 suseme scsi: [ID 107833 kern.notice]ASC: 0xc (write error), ASCQ: 0x0, FRU: 0x0

Nov 23 01:01:53 suseme scsi: [ID 107833 kern.warning] WARNING: /scsi_vhci/ssd@g600a0b8000178ac000002676429130a7 (ssd46):

Nov 23 01:01:53 suseme Error for Command: write(10)Error Level: Retryable

Nov 23 01:01:53 suseme scsi: [ID 107833 kern.notice]Requested Block: 8715 Error Block: 8715

Nov 23 01:01:53 suseme scsi: [ID 107833 kern.notice]Vendor: SUNSerial Number:

Nov 23 01:01:53 suseme scsi: [ID 107833 kern.notice]Sense Key: Unit Attention

Nov 23 01:01:53 suseme scsi: [ID 107833 kern.notice]ASC: 0xc (write error), ASCQ: 0x0, FRU: 0x0

[2] ===================================================

Nov 23 04:13:10 suseme genu-50[2704]: [ID 559880 local7.crit] crit Device 53: State set to DOWN by SAM-FS. Check device log.

Nov 23 04:13:10 suseme genu-50[2704]: [ID 694869 local7.alert] Volume (50:8) is in drive 53 that is off or down.

[3]==================================================

iostat -En | more

c0t0d0 Soft Errors: 2 Hard Errors: 0 Transport Errors: 0

Vendor: TOSHIBA Product: DVD-ROM SD-M1712 Revision: 1004 Serial No:

Size: 0.00GB <0 bytes>

Media Error: 0 Device Not Ready: 0 No Device: 0 Recoverable: 0

Illegal Request: 2 Predictive Failure Analysis: 0

c1t1d0 Soft Errors: 0 Hard Errors: 0 Transport Errors: 0

Vendor: FUJITSU Product: MAP3735F SUN72G Revision: 1601 Serial No: 0509Q0K1TJ

Size: 73.40GB <73400057856 bytes>

Media Error: 0 Device Not Ready: 0 No Device: 0 Recoverable: 0

Illegal Request: 0 Predictive Failure Analysis: 0

c1t4d0 Soft Errors: 0 Hard Errors: 0 Transport Errors: 0

Vendor: FUJITSU Product: MAP3735F SUN72G Revision: 1601 Serial No: 0509Q0K1T7

Size: 73.40GB <73400057856 bytes>

==============================================

[4905 byte] By [a2@sunsolve] at [2007-11-26 11:45:17]
# 1

I also noticed I have some Hard Errors on some of the devices & No Device: 1

Any help on how to diginto these erros ?

partial output iostat -En :

Media Error: 0 Device Not Ready: 0 No Device: 0 Recoverable: 0

Illegal Request: 0 Predictive Failure Analysis: 0

c10t600A0B80001732A600002F0E429130A6d0Soft Errors: 0 Hard Errors: 1 Transport Errors: 0

Vendor: SUNProduct: CSM100_R_FCRevision: 0612 Serial No:

Size: 546.53GB <546534588416 bytes>

Media Error: 0 Device Not Ready: 0 No Device: 1 Recoverable: 0

Illegal Request: 0 Predictive Failure Analysis: 0

c10t600A0B8000178AC00000267442913027d0Soft Errors: 0 Hard Errors: 1 Transport Errors: 0

Vendor: SUNProduct: CSM100_R_FCRevision: 0612 Serial No:

Size: 546.53GB <546534588416 bytes>

Media Error: 0 Device Not Ready: 0 No Device: 1 Recoverable: 0

Illegal Request: 0 Predictive Failure Analysis: 0

c10t600A0B80001732A600002F0B4290B53Ed0Soft Errors: 0 Hard Errors: 1 Transport Errors: 0

Vendor: SUNProduct: CSM100_R_FCRevision: 0612 Serial No:

Size: 268.44GB <268435456000 bytes>

Media Error: 0 Device Not Ready: 0 No Device: 1 Recoverable: 0

Illegal Request: 0 Predictive Failure Analysis: 0

c10t600A0B8000178AC0000026724290B493d0Soft Errors: 0 Hard Errors: 0 Transport Errors: 0

Vendor: SUNProduct: CSM100_R_FCRevision: 0612 Serial No:

Size: 268.43GB <268431261696 bytes>

a2@sunsolve at 2007-7-7 11:54:41 > top of Java-index,Storage Forums,Storage General Discussion...
# 2
Hello,Can anyone please help me decide if these errors are critical or not. This is happening on Sun v890's with 6130's. and a tape backup L500.Thank you for any help,~a2@sunsolve
a2@sunsolve at 2007-7-7 11:54:41 > top of Java-index,Storage Forums,Storage General Discussion...
# 3
I am these errors too. Do you have the disks connected over fiber channel? It could be a fiber cable with a sharp bend in them or a bad transceiver.
fthe_burl at 2007-7-7 11:54:41 > top of Java-index,Storage Forums,Storage General Discussion...
# 4
as I see you have a SAN environment .So can you post you current zoning configuration ?
Petr_ADushkin at 2007-7-7 11:54:41 > top of Java-index,Storage Forums,Storage General Discussion...
# 5
what do you mean by zoning configuration. Can you elaborate please.Thanks!
a2@sunsolve at 2007-7-7 11:54:41 > top of Java-index,Storage Forums,Storage General Discussion...
# 6
there is no zoning for this configuration
a2@sunsolve at 2007-7-7 11:54:41 > top of Java-index,Storage Forums,Storage General Discussion...