fatal system fault : sipr =40000000 with sparcstation 20
Hi,
I have one sparcstation 20 with one CPU supersparc II (75 MHZ), not interne disk but with 2 UltraSCSI and solaris 2.5.1. Sometime, the station boot well with no problem. But when I want to do action (access to one file for example) the system reboot with the message :
==========
Copyright(c) 1983-1996, sun microsystems, Inc.
Fatal system fault: sipr = 40000000
Async fault from module 0 : afsrb301000 afar = 1ff23c80
Aerr0 0 aerr1=0
Panic: fatal asynchronous
==========
The system continue to reboot without stopping.
I have done Stop-A and written the command test-all. Here is the result:
Ok test-all
==================
Testing /memory@0,0
Testing /obio/sunw,fdtwo@0, 700000
Testing floppy disk system . A formatted should be in the drive.
No diskette , or incorrect format.
Self test failed . return code = -1
Testing /obio/zs@0,0
Keyboard present
Testing /obio/zs@0,100000
Testing /iommu@f, e0000000/sbus@f,e0001000/SUNW, fas@3,8800000
CE DMA fill from address ffed4000 for 80 bytes ERROR : DMA hang condition detected ,
ERROR : DMA hang condition detected
ERROR : DMA failed
Adress ffed3001
Expected 1
Observed 0
Selftest failed . Return code = -1
Testing /iommu@f, e0000000/sbus@f,e0001000/SUNW, hme@3,8c00000
Internal loppback test succeded
Transceiver check failed
Self test failed . return code =-1
Testing /iommu@f,e0000000/sbus@f,e0001000/cgsix@2,0
Testing /iommu@f,e0000000/sbus@f,e0001000/ledmad@f,400010/le@f,c00000
Using AUI Ethernet interface
Internal loopback test ?succeeded
External loopback test ?lost Carrier ( transceiver cable problem ?)
Send failed
Using TP Ethernet interface
Internal loopback test ?succeeded
External loopback test ?succeeded
Testing /iommu@f , e0000000/sbus@f , e0001000/espdma@f, 400000/esp@f , 800000
==================
Please I wont to know what is the problem? Thanks very much.