v240 error

Hi Friends,

I am getting the following error from my V240 server, (contains 2 disks)

WARNING: VxVM vxio V-5-3-0 voldmp_errbuf_sio_start: Failed to flush the error buffer 0x52d1978 on device0x1100000002b to DMP

WARNING: /pci@1c,600000/scsi@2 (glm0):

Resetting scsi bus, got incorrect phase from (1,0)

WARNING: /pci@1c,600000/scsi@2 (glm0):

got SCSI bus reset

WARNING: /pci@1c,600000/scsi@2/sd@1,0 (sd1):

auto request sense failed (reason=reset)

it's connected with Storedge 2210, and it is configured with VxVM....

Please give some inputs......

Hardware reboot, Change of scsi cable nothing helped us....

regds

vj.

[706 byte] By [vijaysys] at [2007-11-26 9:55:43]
# 1

The device path that in the error message, is for an internal disk not for an external disk.

V240 systems can have as many as four internal hard drives.

That path is to your second disk.

It is a Veritas Volume Manager error.

Do you have the filesystems mirrored and encapsulated?

Glance inside Spectrum InfoDoc 21216 for device paths of a few systems:

http://sunsolve.sun.com/handbook_pub/Systems/Example/documents/21216.html

rukbat at 2007-7-7 1:16:57 > top of Java-index,General,Maintenance...
# 2

Hi

Thanks for the reply, the filesystems were mirrored with Raid5....

so, as per the warning message, disk1(the second disk) is having some problem (disk0 is fine)....

this is the output of vxdisk -list

DEVICETYPEDISK GROUPSTATUS

Disk_0auto:slicedrootdiskrootdgonline

Disk_1auto:cdsdiskdatadg04datadgonline dgdisabled spare

Disk_2auto:cdsdiskdatadg01datadgonline dgdisabled failing

Disk_3auto:cdsdiskdatadg03datadgonline dgdisabled

Disk_4auto:cdsdiskdatadg02datadgonline dgdisabled

Disk_5auto:slicedrootmirrorrootdgonline

Disk_6auto:none--online invalid

Disk_7auto:cdsdisk--online

Disk_8auto:cdsdisk--online

Disk_9auto:none--online invalid

Disk_10auto:cdsdisk--online

Disk_11auto:cdsdisk--online

Disk_12auto:none--online invalid

Disk_13auto:cdsdisk--online

Disk_14auto:cdsdisk--online

Disk_15auto:cdsdisk--online

Disk_16auto:cdsdisk--online

Disk_17auto:cdsdisk--online

Disk_18auto:none--online invalid

i got the new disk.... How is it possible to make the system online...

thanks & regds

vijay

vijaysys at 2007-7-7 1:16:57 > top of Java-index,General,Maintenance...
# 3

Hi...

As disk0 gone bad, i tried to boot with disk1 (mirror) but it got stopped with the following ......... can some one help on this....

VxVM INFO V-5-2-3247 starting special volumes ( swapvol rootvol )...

The / file system (/dev/vx/rdsk/bootdg/rootvol) is being checked.

/dev/vx/rdsk/bootdg/rootvol: INCORRECT BLOCK COUNT I=90959 (624 should be 0) (CORRECTED)

/dev/vx/rdsk/bootdg/rootvol: INCORRECT BLOCK COUNT I=91986 (10 should be 0) (CORRECTED)

/dev/vx/rdsk/bootdg/rootvol: UNREF FILE I=90959 OWNER=root MODE=100644

/dev/vx/rdsk/bootdg/rootvol: SIZE=0 MTIME=Sep 6 11:07 2006 (CLEARED)

/dev/vx/rdsk/bootdg/rootvol: FREE BLK COUNT(S) WRONG IN SUPERBLK (SALVAGED)

/dev/vx/rdsk/bootdg/rootvol: 93359 files, 2409056 used, 13084939 free

/dev/vx/rdsk/bootdg/rootvol: (13963 frags, 1633872 blocks, 0.1% fragmentation)

VxVM vxvm-startup2 INFO V-5-2-503 VxVM general startup...

The system is coming up. Please wait.

checking vxfs filesystems

UX:vxfs fsck: ERROR: V-3-20003: /dev/vx/rdsk/rootdg/catalog:Cannot open /dev/vx/rdsk/rootdg/catalog: No such device or address

/dev/vx/rdsk/rootdg/catalog:file system check failure, aborting ...

vijaysys at 2007-7-7 1:16:57 > top of Java-index,General,Maintenance...
# 4

Hi all!

I'm having a similar error on my machine:

WARNING: /pci@1c,600000/scsi@2/sd@1,0 (sd1):

Error for Command: write(10)Error Level: Retryable

Requested Block: 8202125Error Block: 8202125

Vendor: FUJITSUSerial Number: 0416N0A0PB

Sense Key: Unit Attention

ASC: 0x29 (scsi bus reset occurred), ASCQ: 0x2, FRU: 0x0

WARNING: /pci@1c,600000/scsi@2 (glm0):

Resetting scsi bus, got incorrect phase from (0,0)

WARNING: /pci@1c,600000/scsi@2 (glm0):

got SCSI bus reset

WARNING: /pci@1c,600000/scsi@2/sd@0,0 (sd0):

auto request sense failed (reason=reset)

WARNING: /pci@1c,600000/scsi@2 (glm0):

Resetting scsi bus, got incorrect phase from (2,0)

WARNING: /pci@1c,600000/scsi@2 (glm0):

got SCSI bus reset

WARNING: /pci@1c,600000/scsi@2/sd@2,0 (sd2):

auto request sense failed (reason=reset)

The sun fire V240 has 4 disks but I'm only using 3.

It seems the 3 are having problems...

I worked fine with this machine for a long time without any problem but now (almost once a day) it blocks and shutdown.

It's odd having a problem in the all 3 disks, is the problem in the controler?

Can it be caused by over-heating?

Can anyone help me?!:)

Thanks in advance!

Carina.