v240 error
Hi Friends,
I am getting the following error from my V240 server, (contains 2 disks)
WARNING: VxVM vxio V-5-3-0 voldmp_errbuf_sio_start: Failed to flush the error buffer 0x52d1978 on device0x1100000002b to DMP
WARNING: /pci@1c,600000/scsi@2 (glm0):
Resetting scsi bus, got incorrect phase from (1,0)
WARNING: /pci@1c,600000/scsi@2 (glm0):
got SCSI bus reset
WARNING: /pci@1c,600000/scsi@2/sd@1,0 (sd1):
auto request sense failed (reason=reset)
it's connected with Storedge 2210, and it is configured with VxVM....
Please give some inputs......
Hardware reboot, Change of scsi cable nothing helped us....
regds
vj.
[706 byte] By [
vijaysys] at [2007-11-26 9:55:43]

# 1
The device path that in the error message, is for an internal disk not for an external disk.
V240 systems can have as many as four internal hard drives.
That path is to your second disk.
It is a Veritas Volume Manager error.
Do you have the filesystems mirrored and encapsulated?
Glance inside Spectrum InfoDoc 21216 for device paths of a few systems:
http://sunsolve.sun.com/handbook_pub/Systems/Example/documents/21216.html
# 2
Hi
Thanks for the reply, the filesystems were mirrored with Raid5....
so, as per the warning message, disk1(the second disk) is having some problem (disk0 is fine)....
this is the output of vxdisk -list
DEVICETYPEDISK GROUPSTATUS
Disk_0auto:slicedrootdiskrootdgonline
Disk_1auto:cdsdiskdatadg04datadgonline dgdisabled spare
Disk_2auto:cdsdiskdatadg01datadgonline dgdisabled failing
Disk_3auto:cdsdiskdatadg03datadgonline dgdisabled
Disk_4auto:cdsdiskdatadg02datadgonline dgdisabled
Disk_5auto:slicedrootmirrorrootdgonline
Disk_6auto:none--online invalid
Disk_7auto:cdsdisk--online
Disk_8auto:cdsdisk--online
Disk_9auto:none--online invalid
Disk_10auto:cdsdisk--online
Disk_11auto:cdsdisk--online
Disk_12auto:none--online invalid
Disk_13auto:cdsdisk--online
Disk_14auto:cdsdisk--online
Disk_15auto:cdsdisk--online
Disk_16auto:cdsdisk--online
Disk_17auto:cdsdisk--online
Disk_18auto:none--online invalid
i got the new disk.... How is it possible to make the system online...
thanks & regds
vijay
# 3
Hi...
As disk0 gone bad, i tried to boot with disk1 (mirror) but it got stopped with the following ......... can some one help on this....
VxVM INFO V-5-2-3247 starting special volumes ( swapvol rootvol )...
The / file system (/dev/vx/rdsk/bootdg/rootvol) is being checked.
/dev/vx/rdsk/bootdg/rootvol: INCORRECT BLOCK COUNT I=90959 (624 should be 0) (CORRECTED)
/dev/vx/rdsk/bootdg/rootvol: INCORRECT BLOCK COUNT I=91986 (10 should be 0) (CORRECTED)
/dev/vx/rdsk/bootdg/rootvol: UNREF FILE I=90959 OWNER=root MODE=100644
/dev/vx/rdsk/bootdg/rootvol: SIZE=0 MTIME=Sep 6 11:07 2006 (CLEARED)
/dev/vx/rdsk/bootdg/rootvol: FREE BLK COUNT(S) WRONG IN SUPERBLK (SALVAGED)
/dev/vx/rdsk/bootdg/rootvol: 93359 files, 2409056 used, 13084939 free
/dev/vx/rdsk/bootdg/rootvol: (13963 frags, 1633872 blocks, 0.1% fragmentation)
VxVM vxvm-startup2 INFO V-5-2-503 VxVM general startup...
The system is coming up. Please wait.
checking vxfs filesystems
UX:vxfs fsck: ERROR: V-3-20003: /dev/vx/rdsk/rootdg/catalog:Cannot open /dev/vx/rdsk/rootdg/catalog: No such device or address
/dev/vx/rdsk/rootdg/catalog:file system check failure, aborting ...
# 4
Hi all!
I'm having a similar error on my machine:
WARNING: /pci@1c,600000/scsi@2/sd@1,0 (sd1):
Error for Command: write(10)Error Level: Retryable
Requested Block: 8202125Error Block: 8202125
Vendor: FUJITSUSerial Number: 0416N0A0PB
Sense Key: Unit Attention
ASC: 0x29 (scsi bus reset occurred), ASCQ: 0x2, FRU: 0x0
WARNING: /pci@1c,600000/scsi@2 (glm0):
Resetting scsi bus, got incorrect phase from (0,0)
WARNING: /pci@1c,600000/scsi@2 (glm0):
got SCSI bus reset
WARNING: /pci@1c,600000/scsi@2/sd@0,0 (sd0):
auto request sense failed (reason=reset)
WARNING: /pci@1c,600000/scsi@2 (glm0):
Resetting scsi bus, got incorrect phase from (2,0)
WARNING: /pci@1c,600000/scsi@2 (glm0):
got SCSI bus reset
WARNING: /pci@1c,600000/scsi@2/sd@2,0 (sd2):
auto request sense failed (reason=reset)
The sun fire V240 has 4 disks but I'm only using 3.
It seems the 3 are having problems...
I worked fine with this machine for a long time without any problem but now (almost once a day) it blocks and shutdown.
It's odd having a problem in the all 3 disks, is the problem in the controler?
Can it be caused by over-heating?
Can anyone help me?!:)
Thanks in advance!