SMC and System controllers problem
Hi,
I installed a SMC 3.5.1 in a system controller to monitor the entire platform, I configured a email alert but I received the next message:
Alert: sc0 Config Reader (Sun Fire High-End Systems) A Status Domain A - Domain Status is: In Recovery
But the domain has not been restart.
$ uptime
12:28pm up 52 day(s), 2:41, 6 users, load average: 2.35, 2.49, 2.66
Another doubt is that when is desired to modify the alert, it does not save changes SMC, I have found that reinitiating the SMC demons (in System Controller), everything it works correctly, there is another form to correct this?
Thanks in advance.
[658 byte] By [
ctemp1] at [2007-11-26 7:39:01]

# 1
Hi ctemp1,
> Alert: sc0 Config Reader (Sun Fire High-End
> Systems) A Status Domain A - Domain Status is: In
> Recovery
>
>But the domain has not been restart.
> $ uptime
> 12:28pm up 52 day(s), 2:41, 6 users, load
> average: 2.35, 2.49, 2.66
SunMC is forwarding the status detected by your SMS daemons: so uptime probably isn't showing the whole story. Try a SMS command like "showenvironment -d A" and see what's reported.
Also what version of SMS are you running? SunMC has an update available for the new SC hardware, USIV uniboards, and newer versions of SMS that change the SunMC addon from the name "12k-15k" to "High-end Systems":
http://www.sun.com/download/products.xml?id=431df39d
If it looks like there's a mismatch between what SunMC and SMS are reporting, and you're running a newer version of SMS (i.e. 1.5) then you should give that update a try.
Regards,
Mike.Kirk@HalcyonInc.com
http://www.HalcyonInc.com