Sun V480 with StorEdge A3500/A3500FC (raid)

Hi All

I've this sun v480 with Solaris 8. Connected to it is a StorEdge A3500/3500FC.

I think I only see one disk of this raid system, so can someone give me suggestion how to mount this think and/or where to look for information ?

Thanks a lot in advance

Luca

[383 byte] By [Luca] at [2007-11-25 22:45:08]
# 1

Hi,

StorEdge A3500 are hardware-based raid array. You manage the array (add/delete LUN) using a software called 'Raid Manager'. Current version at 6.22.1.

If under format, you can see the disk, you can however use native Solaris disk slices to partition it or use SVM software to do it.

SLIM at 2007-7-5 16:57:05 > top of Java-index,Sun Hardware,Other Sun Hardware...
# 2
Luca, are you seeing a LUN? Print the output of format.
mlennon at 2007-7-5 16:57:05 > top of Java-index,Sun Hardware,Other Sun Hardware...
# 3

Here are the results from....format:

Searching for disks...done

AVAILABLE DISK SELECTIONS:

0. c1t0d0 <SUN36G cyl 24620 alt 2 hd 27 sec 107>

/<a href="mailto:pci&#64;9" target="_blank">pci@9</a>,600000/SUNW,<a href="mailto:qlc&#64;2" target="_blank">qlc@2</a>/<a href="mailto:fp&#64;0" target="_blank">fp@0</a>,0/<a href="mailto:ssd&#64;w2100002037cfdf9d" target="_blank">ssd@w2100002037cfdf9d</a>,0

1. c1t1d0 <SUN36G cyl 24620 alt 2 hd 27 sec 107>

/<a href="mailto:pci&#64;9" target="_blank">pci@9</a>,600000/SUNW,<a href="mailto:qlc&#64;2" target="_blank">qlc@2</a>/<a href="mailto:fp&#64;0" target="_blank">fp@0</a>,0/<a href="mailto:ssd&#64;w2100002037cfd30e" target="_blank">ssd@w2100002037cfd30e</a>,0

2. c3t5d0 <Symbios-StorEDGEA1000-0003 cyl 65533 alt 2 hd 64 sec 67>

/pseudo/<a href="mailto:rdnexus&#64;3" target="_blank">rdnexus@3</a>/<a href="mailto:rdriver&#64;5" target="_blank">rdriver@5</a>,0

3. c3t5d1 <Symbios-StorEDGEA1000-0003 cyl 65533 alt 2 hd 64 sec 67>

/pseudo/<a href="mailto:rdnexus&#64;3" target="_blank">rdnexus@3</a>/<a href="mailto:rdriver&#64;5" target="_blank">rdriver@5</a>,1

Do I see only 1 disk in this raid system ?

I don't know anything about LUNS, so your help is very useful!!!

Thanks

Luca

Luca at 2007-7-5 16:57:05 > top of Java-index,Sun Hardware,Other Sun Hardware...
# 4

You are seeing the RAID controller at c3t5. It is seeing two LUNS, c3t5d0 & c3t5d1. Each LUN can consist of multiple disk drives. As SLIM mentioned, you need RAID Manager (RM6) to manage which disks are associated with which LUNS. You are OK from a hardware aspect. Now you need to use software (RM6) to proceed further.

jds2n at 2007-7-5 16:57:05 > top of Java-index,Sun Hardware,Other Sun Hardware...
# 5
Luca, was this array already a production system before you attached the V480? If it was I suggest that you check and see if there is a host running RAID manager already.
mlennon at 2007-7-5 16:57:05 > top of Java-index,Sun Hardware,Other Sun Hardware...
# 6

This system was an operational system before. The only thing I did was that I've installed a new OS.

I've download the raidmanager 6.22.1 and all the documentation, its a lot. So far I've upgraded some firmware succesfully.

It wil take me some time to read an try it out. I'll be back later!!

Cheers

Luca

Luca at 2007-7-5 16:57:05 > top of Java-index,Sun Hardware,Other Sun Hardware...