StorEdge A3500 thinks it is an A1000
hello all,
i have a problem with a StorEdge A3500 controller that has five D1000
attached to it. using the detailed controller information in rm 6.22.1 i
saw that controller A thinks it is a A1000 (it shows Product ID:
StorEDGE A1000) all other details a normal.
by default A is active and B is passive - in this situation i can only
see 8 disks (4 from tray 1 and 4 from tray 2 - all other 32 disks are
not shown). if i switch the roles of the controllers and make B active
and A passive then everything is ok. i can see all 40 disk, create luns,
etc.
firmwares of both controllers is the same:
. boot level: 03.01.04.00
. firmware level: 03.01.04.75
both controllers have the same product revision: 0301
do you have a clue what this could be ?
i was thinking of downgradind both of the controllers to firmware
03.01.02.35/03.01.02.33 but i am not sure if this will help.
thank you for your time!
Stoyan Angelov
--
Stoyan Angelov
filibeto.org
e-mail: s_angelov@filibeto.org
http://www.filibeto.org