Errot at boot !!!

Today I was trying to boot ..and got following error.Fatal SCSI error script 8 illegal opertation Drive is not readyPlease advise.FromP
[184 byte] By [pthaker] at [2007-11-25 23:00:00]
# 1
Please describe your configuration.
maal at 2007-7-5 17:49:08 > top of Java-index,Storage Forums,Storage General Discussion...
# 2
E450.I can get to the boot prompt Sun OS 2.6On the back there are 2 serial ports A and Band the power cord.Please let me know soon.Thanks again.FromP
pthaker at 2007-7-5 17:49:08 > top of Java-index,Storage Forums,Storage General Discussion...
# 3

Hello Pranav,

did you change anything between the last successful boot and now ?

<i>Drive is not ready</i>

Issue <b>probe-scsi</b> to check if all disks are detected. I think at least one of the drives will be missing (the failed one).

Try to reseat the drive. Review the E450 User's Guide for the drive numbering/location in the trays and of cause trouble shooting procedures.

Using a console cable allows to capture the output and view the diagnostics information.

Review the following thread for instructions

<a href="http&#58;&#47;&#47;supportforum.sun.com/hardware/index.php?t= msg&amp;th=3542&amp;start=0&amp;rid=23&amp;SQ=9c4d61fc9b1d8ce9bb 240028974aadac" target="_blank"><b>How to connect to Sun Systems via TIP</b></a>

Michael

maal at 2007-7-5 17:49:08 > top of Java-index,Storage Forums,Storage General Discussion...
# 4

With the lack of information I will take a shot in the dark!

First basic line of defense when looking to troubleshooting hardware issues is to boot cdrom(ok> boot cdrom -sw).

Make sure you can see all the disks/hardware that should be present.

For better troubleshooting you really should supply: Server model, OS level, disk configuration, attached peripherals(Tape drives, etc. ), better/cut-N-paste/hand tyed of boot messages where system stops, known software installed(ie- veritas, Disksuite, etc.), changes to system lately, time of last successful reboot, patch levels(Not that it really matters for 2.6), etc.

error at 2007-7-5 17:49:08 > top of Java-index,Storage Forums,Storage General Discussion...
# 5

Hello "error",

it was my fault to try to answer his (pthaker) question. When I asked him to post his <b>configuration</b>, the type of system and operating system weren't indeed suficient.

It wasn't his first inquiry on these forums, but as in his previous posts, he hesitated or is incapable to provide the requested information.

Michael

maal at 2007-7-5 17:49:08 > top of Java-index,Storage Forums,Storage General Discussion...
# 6
Michael,It just makes it easier on us to help. More information or to much information never hurts. Sometimes a past action or change will ring a bell about a bug or patch.
error at 2007-7-5 17:49:08 > top of Java-index,Storage Forums,Storage General Discussion...