SMC and SNMPv3

398 byte By jd3835 at 2007-11-26 5:58:34
Hello,I've noticed that this forum is not very widely used, but I'm hoping somebody checks it and can help me out. I need to use the SNMPv3 functionality of SMC, and I'm hoping that the SNMP agent included with SMC can act as a master agent. I need to use the SNMP subagent of Sun ONE ...

Solaris 10

375 byte By arutherford2 at 2007-11-26 5:58:36
Hi,does anyone know what version of SMC will support Solaris 10? I see that SMC 3.0 works on Solaris 8, and SMC 3.5 works on Solaris 9, so I'm wondering if a new version of SMC will come out to work with Solaris 10.We are currently using SMC 3.0 under Solaris 8 and are considering moving to ...

SMC system management options.

475 byte By fboisseau2 at 2007-11-26 5:58:37
I have been trying to install the SMC 3.5 on my SunFire V120 run Solaris 9, thinking that it would allow me to manage users and printers. When I finally got the base system installed all I had was what looked like the proformace monitor options. The two question I have is first does the SMC ...

Very basic questions about SMC

521 byte By acravens at 2007-11-26 5:58:38
I've never used SMC before and I have some basic questions. I'm trying to set up the Sun Management Colsole to manage LDAP users in accordance with the instructions in Tom Bialaski's book LDAP IN THE SOLARIS OPERATING ENVIRONMENT.My questions are:1) What's the difference between Sun ...

C++ App registering for traps?

670 byte By arutherford2 at 2007-11-26 5:58:40
Hi,I'm new to SMC. I am trying to find a way to have traps forwarded to a C++ application. I found the section in the SMC 3.0 Developers manual about trap subsrcription (in Appendix G). I see that you can have the traps forwarded to an IP/port. So I guess I have two questions:1) how do I ...

280R black splats

529 byte By stanglinden at 2007-11-26 5:58:41
I am having problems getting a 280R to fully work with SunMC 3.5 u1.The system is black splating for all the Hardware modules. The message given on mouse over on the system is "Config Reader (VSP High End Servers) Entry Number Failed to Update/The system reports as s Sun4u-SunFire-280R-vh from ...

SunFire V440 and SMC 3.5 Update 1

230 byte By Adrian_609 at 2007-11-26 5:58:42
I have 3 SunFire V440 servers in network and SMC 3.5 Upd 1 shows me only a folder for each of them, with no acces to alarms, hardware ....How could be fixed that ?On servers I have Solaris 8.Thank you !

Sun MC 3.5 Hot Standby server layer

214 byte By mjkiv11 at 2007-11-26 5:58:43
IHAC that wishes to run a second Sun MC 3.5 server layer in a hot standby mode.Does anyone know if this is possible and if so, advise of any documentation on how to do this.RegardsMartin

Netra 240 supported by SunMC

300 byte By luisfe3 at 2007-11-26 5:58:44
I've a Netra 240, but I can see in http://wwws.sun.com/software/solaris/sunmanagementcenter/supported_platforms.ht ml, that it's not supported by SunMC.Someone knows when Netra 240 will be supported by SunMC ?If not, any suggestions ?Thanks in ...

SunMC 3.0 and 3.5 - E450 and ultra10 black splat problem

1710 byte By upsl01 at 2007-11-26 5:58:45
Hi all,Don't know if this is the right forum, but if not, then I am sure you will re-direct me.I have just recently configured up all of our Sun servers, ranging from 3800's Exxx and new SunFire 210's 240's 880's 440's etc. All are now working fine with a little help from the Forum ...

Problem with tar compatibility between AIX and Solaris 5.9

1951 byte By atengatt at 2007-11-26 5:58:46
Hi,I have a big problem with tar. Ok, let me explain.......We must migrate some data prepared with AIX Unix on DDS-3 4mm Tapes with thecommand "tar -cvf /dev/rmt/0" (nothing special) andneed to import this data into our SunOS (Solaris 5.9) system with thecommand "tar -xvf /dev/rmt/0 ./2002". ...

invalid value for critical action error

229 byte By Ozone_Malone at 2007-11-26 5:58:47
When trying to configure email notifications for the Directory Monitor module I get an "invalid value" error for any of the action levels. ANybody else experiencing this problem? Very frustrating. Solaris 8; SMC 3.5

280R Sun Cluster 3.0 can't acknowledge blue alarm

1151 byte By upsl01 at 2007-11-26 5:58:48
Hi,We have 2 x 280R's in a sun cluster 3.0 configuration. We have sunmc 3.5 agent installed. My problem is that the resource group shows with one node offline (which is obviously correct, as both nodes should not have the resources at the same time). I am fine with the event showing, but I can ...

SMC for homegrown Java apps

1061 byte By grandcanuck at 2007-11-26 5:58:49
This may be a bit OT but we are currently researching and gathering info on SMC.We currently use BMC Patrol (and a lot of PSL scripts) to monitor all of our homegrown Java applitions. Most of the functions we use to monitor are:* reading and parsing a file from disk* reading and parsing output ...

SMC 3.5 module info

474 byte By esmadm at 2007-11-26 5:58:50
Hello,I'm the process of configuring SMC 3.5 and have the following queries :1. How does one obtain filesystem capacity info? There doesn't appear to be a native module for this, yet there are Directory and File size modules which aren't the same thing..2. There doesn't appear to be any ...

Creating Agent Fails . . . Problem with SNMP?

1032 byte By TnTSysAdmin at 2007-11-26 5:58:51
I have successfully added one agent (Ultra 10) to the SMC server (E4500) however I am unable to get another agent (Ultra 10) to be created. The error "Cannot find agent process. Please check host/port." is displayed in the Create Topology Object window. I have gone thru the forum and found some ...

SMC 3.5 SC Monitoring problem

2373 byte By esmadm at 2007-11-26 5:58:52
Hello,I've come across a problem whilst attempting to load the SC Monitoring module on some System Controllers. The load attempt hangs for about 30 secs and fails with : "Unable to load module definition". The entire Systems Controller Admin domain then greys out and all sub-views disappear. ...

File Monitoring Alarm test change

439 byte By Ozone_Malone at 2007-11-26 5:58:53
Out of the box the File Monitoring module tests for file growth greater than your given ceiling, however I want to test for the opposite, file growth being less than the supplied limit. Scanned the associated modules files for a quick reversal on the test and I've come up with nothing. Having ...

Exploring SMC Change Manager for Data Center server builds

808 byte By implicate_order at 2007-11-26 5:58:54
I have worked on server builds on a large scale using Jumpstart + Flash and/or Live Upgrade. Recently I got an opportunity to be part of the build process from scratch and was investigating various options I had for the builds.I came up with a set of rules that my build mechanism would have to ...

SMC 3.5 & StorADE and SunMC Provider

1171 byte By reclspeak at 2007-11-26 5:58:55
Hello,I am a little perplexed with an installation of the SunMC provider for StorADE, caused by some confusing "Best Practises" documentation in the storADE getting started guide and elsewhere.I have a single server that is acting as a SMC Console & Server (with agent) installed - Server AI ...

SMC 3.5.1 Console on Windows XP install fails

654 byte By esmadm at 2007-11-26 5:58:56
Hello,I'm trying to install the SunMC 3.5.1 Console on Windows XP with not much success. The install displays the initial splash screen, but then fails with the error : The install wizard cannot proceed. Aborting installation now...The Java version is 1.4.2_03 . The Release Notes etc don't ...

Setup Sun Management Center 3.5

316 byte By tcerg at 2007-11-26 5:58:57
I' m installing SMC 3.5 on Solaris 9 (sparc platform SunFire v210). Installation was successfully, but setup was not successfully.Generating server security keys.Error generating keys. Return code was 1.Help me!Sorry for my English :-)Sergei ...

SNMP Triggers in SMC ?

240 byte By esmadm at 2007-11-26 5:58:58
Hello,Is it possible to run a command based upon receiving a particular SNMP event? We're looking at integrating HP TelAlert with SunMC and how SNMP events can be handled by SMC etc.Thanks in advance.John

Upgrade from 1.0 to 3.5?

360 byte By farrelli at 2007-11-26 5:58:59
Howdy,I've got an E350 that's running Solaris 8 and SMC 1.0 and I want to upgrade to SMC 3.5 but I can't seem to find documentation on how to do this. The best I've found is upgrading from 2.X to 3.5 but that ain't gonna cut it. Anybody done this or know where I might be able to get the ...

sun v880 error help

390 byte By screenboy at 2007-11-26 5:59:00
Nov 28 17:04:13 v8801 inetd[254]: [ID 858011 daemon.warning] /usr/dt/bin/rpc.ttdbserverd: HangupNov 28 17:04:14 v8801 rpc.ttdbserverd[2276]: [ID 862439 daemon.error] NetISAM: read failed: requested 1024 bytes, got 0Nov 28 17:04:14 v8801 ToolTalk/ISAM[2276]: [ID 314109 user.error] Fatal error: ...

SMC agents on 12K/15K

426 byte By Artie at 2007-11-26 5:59:03
Looking for some insight on the installation of the domain agents and monitoriing for SMC on the 12K and 15K domains.Each attempt at installation results in just the non-English locale message files being installed for the monitoring agent and no DR agent installaion. It appears that es-inst ...

SMC 3.5 to monitor a Linux PC

94 byte By ewolf@nortel at 2007-11-26 5:59:04
Will SunMC 3.5 monitor a Linux machine? How about a VxWorks OS/Filesystem?Thanks

Developing across platform Agents

290 byte By SUN-X-SUPPORTER at 2007-11-26 5:59:06
HelloI have two questions to ask.1. Is there any plans to develope cross platform agents is for HP?If you did it would make Sun Management center award winning product.Is there any plans to bring out agent pack kits for eg:5, 10 , 15, 20, etc, etc to buy.

File System monitoring - How can I ensure this ?

618 byte By Maurice_XOG at 2007-11-26 5:59:08
I need to ensure that SunMC not only reports when a file system meets/exceeds its limit, but also that it reports it periodically there after till its under the limit.The problem I just had was a DBA file system filled up, the DBA's were auto notified about their file system, they logged on ...

fan speed and CPU Temp

115 byte By VDSI-SPK at 2007-11-26 5:59:11
Is there a command that shows current fan speed? How about CPU Temp? I am using Solaris 8 on a 280r and 220.

Can't acknowledge alarms on some clients

301 byte By hollyja at 2007-11-26 5:59:15
With certain clients, it appears there is full functionality (load/unload modules, monitor, etc.) with the exception of acknowledging alarms. When an attempt is made to acknowledge an alarm, the error message is "...No response from agent."Any help is greatly appreciated!J. ...

Need monitoring

227 byte By spaigejr at 2007-11-26 5:59:16
OK, we have SunMC deployed in about 90% of our envirnoment. Where should I start for some sort of Notifictions on alerts? Like to start out with the small stuff. Filesystem sizes, host down, etcThanks!Steve

Halcyon EventAction

146 byte By spaigejr at 2007-11-26 5:59:17
Anyone out there using the Halcyon EventAction module? Feedback? Looks like a great product. How expensive is it?Thanks!Steve

using net-snmp to read data from SMC?

414 byte By arutherford2 at 2007-11-26 5:59:19
Hi, we are currently using SMC 3.0 (about to upgrade to version 3.5). I'm interested in using net-snmp so that I can get access to the SNMP data residing in SMC via various C++ applications.Can this be done without running a net-snmp agent or sub-agent? I would prefer to leave SMC as the only ...

help! snmp without SMC!

195 byte By tyllor at 2007-11-26 5:59:20
In SOE,how to setup snmp config file (/etc/snmp/conf/snmpd.conf)to send trap to the-third party(no SMC intallation)on v880 or v480.who pls give me document for this on v880 or v480?

Monitoring!!

286 byte By Chimp00 at 2007-11-26 5:59:21
I Need to monitor the following entities....1)Linux Redhat AS 3.0 (Cpu,memory,disk,swap)2)3com 3300 switch (Runs rmon probe)3)3350 storage arrayCan SMC 3.5 monitor all of above or do I need a combination of SMC and Sun Storedge or any 3rd party tool.?

Agent on non standard port

691 byte By zeroburn at 2007-11-26 5:59:22
I'm having a problem with the agent on a specific machine, a V480 running Solaris 9. I have installed using the same image as a number of other machines, the only difference being post install I have changed the agent port from 161 to 4161 using es-config command and when the agent restarts it ...

V890 SMC Agent

226 byte By Omar@BigAdmin at 2007-11-26 5:59:23
Hi AllI've installed SMC and the hardware module for all systems other than the V890 is working. I've tried to search everywhere but cannot seem to find any modules for the V890. Any help appreciatedOmar

V880 Hardware View

389 byte By WilArtman at 2007-11-26 5:59:24
After installing SunMC v3.5 sucessfully on the server and various clients, I find that the hardware view for the V880's gives the following error:"Hardware Summary Information not available"I've verified the base and agent installations with es-validate.All other clients seem to display the ...

Upgrade from 3.5 to 3.51

169 byte By plr at 2007-11-26 5:59:25
Anybody done this yet? Any problems? Do you have to upgrade all the agents as well or can you upgrade your server console and then gradually upgrade your agents ?

Black splat on an Ultra5

778 byte By EMRP at 2007-11-26 5:59:27
Hello,I'm testing SMC35u1. Installation went fine on server and one agent (U5). In the console, the U5 icon has this black splat with the following error message:Config Reader (Workgroup Server) tree prop Failed to Update.The agent log file contains the following lines:[000002cf 0061 ]errorMar ...

Alarms not working, loading, displaying.

870 byte By sunitup at 2007-11-26 5:59:29
Hello,Did any one get to the bottom of the Alarm not appearing under SunMC? I have active alarms which do not appear under the Alarms Tab. I've tried all suggestions on this Forum, reseeding, moving agent files out the way, checking the info tab.One one system agent I get "Unable to get event ...

Retrieve Information

282 byte By plr at 2007-11-26 5:59:30
Anybody have an easy way to query the sunmc server and get it to list all its agents and their loaded modules and patch levels? There used to be a script in version 3 that did this, but it is no longer there in 3.5 and es-validate doesnt list all the agent info.Thanks

Agent on Solaris 10

558 byte By dferch_de at 2007-11-26 5:59:31
Hello,we are running SunMC 3.5up1 on Solaris 9. I installed a new server with Solaris 10 and the SunMC 3.5up1a Agent in the global zone. The agent starts fine, but I can't connect from SunMC server. I only got warnings on snmp-reports in agent.log.How can I debug this problem in a more ...

New to SMC

671 byte By ks49rcng at 2007-11-26 5:59:33
New to SMC. Have SMC 3.5 server running on a Sun-Fire-V210 with Solaris 9 OS.When I run es-validate -a <agent> -b <snmp agent port>, I get the following output.-Checking connecitivity to agent host mentioned with -a command line option-Connection to host <hostname> is alive. ...

hme0 problem

504 byte By manish_velankani at 2007-11-26 5:59:34
I have solaris 6 installed.During the time of setup it accepts the Ip which I feed and is reachable.When installation completes and I reboot the system the system becomes unreachable and there is an infoLink Down Cable problem.If I run the command "ifconfig hme0 down" then the link light starts ...

Getting config reader to work on various platforms - requirements?

1233 byte By JCricket at 2007-11-26 5:59:36
So far, it appears that on two different architectures (E250/E450 versus V210) I have had to install different add-ons in order to get config reader working so that SunMC can monitor hardware (our ultimate goal). On the E250/E450 I had to include the "Workgroup Server" add-on. On my V210 the ...

Sun Blade 100

612 byte By ks49rcng at 2007-11-26 5:59:37
Installed the smc 3.5 agent on a sun blade 100. Could create an object for the agent in the smc console but it was showing up as a file folder and only showing 2 tabs - info and module. After searching found that the Desktop add-on is needed on the server and the agent to manage a Sun Blade ...

SunMC 3.5.1 and Netra Config Reader

239 byte By Robert.Hayne@shaw at 2007-11-26 5:59:41
I have a single netra T1 10x system that when added to sunmc diplays a "Netra t Config Reader Module Status system: Data acquisition error"Has anyone seen this? I need someone to point me in a direction to resolve this issue.

I'm really tired of this now

671 byte By Elvismen at 2007-11-26 5:59:42
do anyone want to get a netra t1 105?is free, i'm can't deal with this solaris thingi setup my network with 9 server running my own DNS zone to webserver and streaming server, i buy the netra to use it as a dns server but this is next to imposible to do for me, windows is sooo easy.oh well i ...